Bottle Quality CommentsΒΆ

Station

Cast

Bottle

Param

Code

Comment

1

1

6

SALNTY

3

fresh, may be early closure

1

1

6

REFTMP

3

warm, rosette winched upward before acquisition finished

2

1

4

SALNTY

3

salty, may be early closure. bottle was leaking

4

1

12

SALNTY

3

much fresher than 13 (fired ~same depth), may be mis-sampled from bottle 14

5

1

2

SALNTY

3

fresh, may be late closure

5

1

5

SALNTY

3

a bit fresher than neighbors, may be late closure

5

1

32

REFTMP

3

warm, measurement may include air temp

6

1

11

SALNTY

3

fresh, may be late closure

6

1

12

SALNTY

3

fresh, may be late closure

6

1

31

SALNTY

3

salty, may be early closure

6

1

33

REFTMP

3

cold, insufficient stop time in gradient, may include air temp

7

1

4

SALNTY

3

salty, may be early closure or sampling error

7

1

11

SALNTY

3

fresh, may be late closure

8

1

1

SALNTY

3

salty, may be sampling error

8

1

32

REFTMP

3

warm, insufficient stop time in sharp gradient

9

1

22

REFTMP

3

warm, insufficient stop time in sharp gradient

9

1

30

SALNTY

3

salty, may be late closure. started having comms errors shortly after

10

1

2

SALNTY

3

fresh, may be sampling error

10

1

29

SALNTY

3

fresh, may be early/late closure or insufficient stop time

10

1

33

SALNTY

3

fresh, may be late closure or insufficient stop time

10

1

33

REFTMP

3

high variability, insufficient stop time in sharp gradient

10

1

34

SALNTY

3

fresh, may be late closure or insufficient stop time

10

1

35

SALNTY

3

fresh, may be late closure or insufficient stop time

11

1

35

SALNTY

3

very salty, may be early closure or insufficient stop time

11

1

35

REFTMP

3

cold, high variability, insufficient stop time in sharp gradient

12

1

1

SALNTY

3

salty, may be early/late closure or sampling error

12

1

8

SALNTY

3

salty, likely sampling error. autosal had difficulty finding good reading

12

1

32

SALNTY

3

fresh, may be late closure or insufficient stop time

12

1

32

REFTMP

3

cold, rosette winched upward before acquisition finished

12

1

35

SALNTY

3

salty, may be early closure or insufficient stop time

13

1

3

SALNTY

3

salty, may be early/late closure or sampling error

13

1

6

SALNTY

3

salty, may be late closure

15

1

4

Bottle

4

Nutrients and O2 do not appear to fit the profilei; mistrip

16

1

1

SALNTY

3

salty, may be early/late closure

18

1

2

SALNTY

3

salty, may be early or late closure

18

1

12

SALNTY

3

salty, may be late closure

18

1

22

SALNTY

3

too fresh, may be early closure

18

1

28

Bottle

4

Nutrients and O2 do not appear to fit the profilei; mistrip

18

1

28

SALNTY

3

too salty, may be late closure

21

1

13

SALNTY

4

considerably lower than all other samples, likely sampling error

21

1

32

Bottle

4

Nutrients and O2 do not appear to fit the profilei; mistrip

21

1

32

SALNTY

4

possibly early closure or sampling error

24

1

5

SALNTY

3

fresh, may be early closure

25

1

1

SALNTY

3

salty, may be early closure or sampling error

25

1

34

SALNTY

4

extremely fresh for surface, may be an early closure

26

1

20

SALNTY

3

fresh, autosal had trouble finding value

27

1

25

Bottle

4

Nutrients and O2 do not appear to fit the profilei; mistrip

30

1

1

SALNTY

3

salty, may be early/late closure or sampling error

30

1

24

SALNTY

3

fresh, may be early closure or insufficient stop time

31

1

9

SALNTY

3

salty, may be late closure

31

1

32

Bottle

4

O2 draw temp low; nutrients do not fit profile; mistrip

31

1

32

SALNTY

3

way too fresh, suspect early closure

33

1

12

SALNTY

3

salty, may be late closure

34

1

9

Bottle

4

Salt and nutrients appear to match bottle 10; likely mistrip

34

1

9

SALNTY

3

salty, may be late closure

35

1

1

SALNTY

3

salty, may be early or late closure

35

1

11

SALNTY

3

salty, may be late closure

36

1

3

SALNTY

3

salty, may be late closure

36

1

31

SALNTY

3

fresh, may be early closure or insufficient stop time at high gradient

36

1

31

REFTMP

3

cold, insufficient stop time in sharp gradient

38

1

9

SALNTY

3

salty, may be late closure or sampling error

38

1

23

REFTMP

3

warm, rosette winched upward before acquisition finished

39

1

31

SALNTY

3

salty, may be late closure

40

1

2

Bottle

4

nutrients do not fit profile; mistrip

40

1

2

SALNTY

3

too salty, likely early or late closure

41

1

36

SALNTY

3

very fresh, may be early closure

43

1

4

SALNTY

3

fresh, may be early closure

43

1

30

Bottle

4

CTD coms issue; bottle closed at unknown depth

43

1

31

Bottle

4

CTD coms issue; bottle closed at unknown depth

43

1

32

Bottle

4

CTD coms issue; bottle closed at unknown depth

43

1

33

Bottle

4

CTD coms issue; bottle closed at unknown depth

43

1

34

Bottle

4

CTD coms issue; bottle closed at unknown depth

43

1

35

Bottle

4

CTD coms issue; bottle closed at unknown depth

44

1

1

SALNTY

3

salty, may be early closure or sampling error

45

1

2

Bottle

4

O2 draw temp high; nutrients do not fit profile; mistrip

45

1

2

SALNTY

4

very salty, unclear if early or late closure. bottle was much warmer than 1 or 3

45

1

4

SALNTY

3

fresh, may be early closure

46

1

24

SALNTY

3

fresh, may be early closure or insufficient stop time

48

1

2

Bottle

4

O2 draw temp high; oxygen does not fit profile; mistrip

48

1

2

SALNTY

4

far too salty, likely closed early

49

1

31

SALNTY

3

fresh, may be early closure

50

1

14

SALNTY

3

salty, may be late closure. autosal had trouble finding value

52

1

8

SALNTY

3

salty, may be late closure or sampling error

53

1

30

SALNTY

3

fresh, may be early closure

53

1

33

SALNTY

3

salty, may be early closure

54

1

25

SALNTY

3

fresh, may be early closure

54

1

30

SALNTY

3

salty, may be late closure

55

1

29

SALNTY

3

fresh, may be early closure or insufficient stop time

56

1

3

SALNTY

3

salty, may be late closure

56

1

10

Bottle

4

Bottle did not close

56

1

20

REFTMP

3

warm, rosette winched upward before acquisition finished

56

1

22

REFTMP

3

warm, rosette winched upward before acquisition finished

56

1

32

SALNTY

3

salty, may be early closure or insufficient stop time

57

1

23

SALNTY

3

fresh, may be early closure or insufficient stop time

59

1

8

SALNTY

3

salty, may be late closure

59

1

21

SALNTY

3

fresh, possible early closure or mis-sampled

59

1

28

SALNTY

3

fresh, early closure or insufficient stop time

60

1

7

SALNTY

3

salty, may late closure. autosal had trouble finding value

60

1

31

SALNTY

3

fresh, early closure or insufficient stop time

60

1

32

SALNTY

3

salty, early closure or insufficient stop time

61

1

31

SALNTY

3

fresh, early closure or insufficient stop time

61

1

35

SALNTY

3

salty, may be early closure

62

1

30

SALNTY

3

fresh, early closure or insufficient stop time

63

1

2

SALNTY

3

salty, early/late closure or mis-sampled

63

1

27

SALNTY

3

fresh, may be early closure or insufficient stop time

63

1

29

SALNTY

3

fresh, may be early closure or insufficient stop time

63

1

31

SALNTY

3

fresh, may be early closure or insufficient stop time

63

1

32

SALNTY

2

salty, may be early closure or insufficient stop time

64

1

26

SALNTY

3

too salty, likely late closure or mis-sampled

64

1

31

SALNTY

3

fresh, may be early closure or insufficient stop time

64

1

33

SALNTY

3

fresh, may be late closure

65

1

29

SALNTY

3

fresh, may be early closure or insufficient stop time

65

1

30

SALNTY

3

fresh, may be early closure or insufficient stop time

65

1

31

SALNTY

3

fresh, may be early closure or insufficient stop time

66

1

2

Bottle

4

O2 draw temp high; oxygen does not fit profile; mistrip

66

1

2

SALNTY

3

far too salty, late or early closure or mis-sampled

66

1

29

REFTMP

3

warm, rosette winched upward before acquisition finished

66

1

30

SALNTY

3

fresh, may be late closure or insufficient stop time

67

1

2

SALNTY

3

sampler error, unclear what order these were actually sampled in

67

1

3

SALNTY

3

sampler error, unclear what order these were actually sampled in

67

1

4

SALNTY

3

sampler error, unclear what order these were actually sampled in

67

1

11

SALNTY

3

salty, may be late closure or mis-sampled

67

1

12

SALNTY

2

fresh, may be early closure or mis-sampled

67

1

30

SALNTY

3

fresh, may be early closure or insufficient stop time

67

1

32

SALNTY

3

salty, may be late closure

67

1

35

SALNTY

2

salty, may be early closure

68

1

10

SALNTY

3

fresh, may be early closure

68

1

17

SALNTY

3

fresh, may be late closure or mis-sampled

68

1

26

REFTMP

3

warm, rosette winched upward before acquisition finished

68

1

31

SALNTY

3

fresh, may be early closure or insufficient stop time

68

1

32

SALNTY

3

fresh, may be early or late closure or insufficient stop time

68

1

34

SALNTY

3

salty, may be early closure or insufficient stop time

69

1

10

Bottle

4

Bottle did not close

69

1

28

SALNTY

3

fresh, may be early closure

70

1

31

SALNTY

3

fresh, may be early closure or insufficient stop time

70

1

31

REFTMP

3

cold, insufficient stop time in sharp gradient

70

1

34

SALNTY

3

salty, may be late closure

71

1

1

SALNTY

3

fresh, may be early or late closure. autosal had trouble finding value

71

1

30

SALNTY

3

fresh, may be early closure or insufficient stop time

71

1

31

SALNTY

3

fresh, may be early closure or insufficient stop time

71

1

31

REFTMP

3

warm, rosette winched upward before acquisition finished

71

1

35

SALNTY

3

fresh, may be late closure

72

1

5

SALNTY

3

fresh, may be early closure

72

1

6

SALNTY

3

fresh, may be early closure

72

1

7

SALNTY

3

fresh, may be early closure

72

1

30

SALNTY

3

fresh, may be early closure or insufficient stop time

72

1

32

REFTMP

3

cold, insufficient stop time in sharp gradient

73

1

2

Bottle

4

O2 draw temp high; oxygen does not fit profile; mistrip

73

1

2

SALNTY

4

saltier than almost entire cast, very warm compared to bottles 1 and 3

73

1

3

SALNTY

3

salty, may be late closure

73

1

6

SALNTY

3

fresh, may be early closure

73

1

16

SALNTY

3

fresh, may be late closure

73

1

31

REFTMP

3

cold, insufficient stop time in sharp gradient

74

1

16

SALNTY

3

fresh, may be late closure

74

1

27

SALNTY

3

fresh, may be early closure or insufficient stop time

74

1

30

REFTMP

3

cold, insufficient stop time in sharp gradient

76

1

9

SALNTY

3

fresh, may be early closure

76

1

10

SALNTY

3

fresh, may be early closure

76

1

30

SALNTY

3

fresh, may be early or late closure

77

1

29

SALNTY

3

fresh, may be early closure or insufficient stop time

78

1

28

REFTMP

3

warm, rosette winched upward before acquisition finished

78

1

33

SALNTY

3

fresh, may be late closure

79

1

27

REFTMP

3

warm, rosette winched upward before acquisition finished

80

1

26

REFTMP

3

cold, insufficient stop time in sharp gradient

80

1

34

SALNTY

3

fresh, may be late closure

81

1

2

Bottle

4

oxygen does not fit profile; mistrip

81

1

2

SALNTY

3

fresh, may be late closure or mis-sampled

82

1

1

SALNTY

3

fresh, may be early closure

82

1

33

SALNTY

3

salty, may be early closure

82

1

34

SALNTY

3

extremely fresh

83

1

20

SALNTY

3

fresh, may be early closure

83

1

23

SALNTY

3

fresh, may be early closure or insufficient stop time

83

1

24

SALNTY

3

fresh, may be early closure

83

1

33

SALNTY

3

salty, may be insufficient stop time. sharp surface gradient

84

1

17

SALNTY

3

salty, may be late closure

84

1

24

SALNTY

3

fresh, may be late closure

84

1

25

SALNTY

3

very fresh, sharp surface gradient

85

1

6

SALNTY

3

fresh, may be early closure

85

1

6

REFTMP

3

warm, insufficient stop time in gradient

85

1

22

SALNTY

3

fresh, sharp surface gradient

86

1

1

SALNTY

3

salty, may be early or lateclosure

86

1

1

REFTMP

3

warm, insufficient stop time in gradient

86

1

3

SALNTY

3

salty, may be late closure

86

1

5

SALNTY

3

fresh, may be late closure

86

1

9

SALNTY

3

fresh, near sharp gradient

86

1

14

SALNTY

3

fresh, may be late closure

86

1

17

SALNTY

3

fresh, sharp surface gradient

87

1

14

SALNTY

3

fresh, near sharp gradient

88

1

10

SALNTY

3

fresh, near sharp gradient

89

1

1

SALNTY

3

fresh, may be sampling error

89

1

4

SALNTY

3

fresh, may be late closure or sampling error

89

1

5

SALNTY

3

fresh, may be late closure or sampling error

89

1

7

SALNTY

3

fresh, near sharp gradient

90

1

5

SALNTY

3

salty, may be early closure

90

1

6

SALNTY

3

fresh, near sharp gradient